Tapper, 30dB, 340-960/1710-2700/3500-4500/4900-6000MHz, N Female

53,31 excl. VAT

Out of stock, contact sales@capestone.com for delivery times

Commscope CT-30-TUW-Ni6

Capestone articlenumber: COM80014 | Vendor articlenumber: CT-30-TUW-Ni6

Order

Please Log in or register to place orders.

Request a quote?

To receive a customised quote, please Contact our sales team.

Commscope CT-30-TUW-Ni6

Product classification
Regional availability: Asia | Australia/New Zealand | EMEA | Latin America | North America
Product type: Tapper

 

General specifications
Type of device: Tapper
Application: Indoor/Outdoor
Color: White
Inner contact: Silver
Interface: N Female
Exterior contact plating: Trimetal

 

Dimensions
Height: 25 mm
Width: 43 mm
Length: 141 mm

 

Electrical specifications
3rd Order IMD: -163 dBc
3rd Order IMD test method: two carriers of +43 dBm
Insertion loss at frequency band: 0.15 dB @ 1695-2700 MHz | 0.15 dB @ 340-960 MHz | 0.2 dB @ 3500-4500 MHz | 0.2 dB @ 4900-6000 MHz
Frequency band return loss: 19.1 dB @ 3500-4500 MHz | 19.1 dB @ 4900-6000 MHz | 20.8 dB @ 1695-2700 MHz | 20.8 dB @ 340-960 MHz
Average power, maximum: 200 W
Clutch: 30 dB
Coupling tolerance: +1.5/-0.2 dB @ 698-960 MHz | +1.7/-0.3 dB @ 340-698 MHz | +1/-2.5 dB @ 4900-6000 MHz | +2.7/-0.5 dB @ 3500-4500 MHz | ±1 dB @ 1695-2700 MHz
Impedance: 50 ohms
Operating frequency band: 1695 – 2700 MHz | 340 – 960 MHz | 3500 – 4500 MHz | 4900 – 6000 MHz
Peak power, maximum: 3 kW
Reflected power, maximum: 200 W


Environmental specifications

Operating temperature: -35 °C to +85 °C
Relative humidity: up to 100%
Corrosion test method: IEC 60068-2-11, 30 days
Ingress protection test method: IEC 60529:2001, IP67


Regulatory compliance/certifications

Agency | Classification
CHINA-ROHS: Above maximum concentration value
ISO 9001:2015: Designed, manufactured and/or distributed under this quality management system
ROHS: Compliant/exempt
UK-ROHS: Compliant/exempt

Battery (mAh)

0

Battery(mAh)

0